Practice quiz · MRT1 · LIBF

Main property defects

Untimed topic quiz on the defects surveys and valuations most often report: the different routes for damp, timber decay and infestation, ground movement, cracking, Japanese knotweed, asbestos and electrical safety.

Questions
12
Time
Untimed
Pass mark
70%
Format
Knowledge check

Independent practice. Not an official LIBF exam. This sitting is part of a paid pack. Every qualification has a free paper you can sit without buying. Flag a question to jump back to it before you submit. All questions are on one page. Answering one scrolls you to the next; submit at the bottom. Optional tips are on each question if you want a nudge, they never name the answer.

Topics covered

  • Main property defects

Sample questions with answers

The first 3 of the 12 questions in this quiz, with the answer and an explanation for each.

  1. Question 1 · Main property defects

    Owen Hale’s survey finds black mould on a cold external bedroom wall where the vendor dries laundry. The gutters are sound, the render is intact and a damp-proof course was injected two years ago. What is the most likely cause?

    1. A.Rising damp, because the injected damp-proof course has failed and ground moisture is climbing the wall
    2. B.Penetrating damp, because rainwater is entering through cracks in the external render of the wall
    3. C.A leaking supply pipe buried within the masonry, which is soaking the plaster from the inside outwards
    4. D.Condensation, where warm moist indoor air meets a cold surface and ventilation is poor

    Answer: D. Condensation, where warm moist indoor air meets a cold surface and ventilation is poor

    Condensation forms when moisture from drying laundry, cooking and bathing meets a cold wall with poor ventilation, and mould follows. The sound render and gutters point away from penetrating damp, and a recent damp-proof course makes rising damp unlikely. Each moisture route has its own cause and cure, so the cause must be identified before repair.

  2. Question 2 · Main property defects

    A surveyor inspecting a Victorian terrace finds a tide mark of salts about one metre up the ground-floor walls, with decaying skirting boards and no staining upstairs. The gutters and roof are in good order. Which defect does this describe?

    1. A.Condensation from cooking and bathing, which has settled on the lowest and coldest wall surfaces
    2. B.Rising damp, where ground moisture travels up the masonry by capillary action past a missing or defective damp-proof course
    3. C.Penetrating damp, where rainwater is running down from a defective roof covering into the ground-floor rooms
    4. D.Subsidence, where the ground has dropped beneath the foundations and has cracked the wall plaster

    Answer: B. Rising damp, where ground moisture travels up the masonry by capillary action past a missing or defective damp-proof course

    Rising damp is ground moisture drawn up through masonry by capillary action where the damp-proof course is missing, bridged or defective, leaving a tide mark of salts low on the wall. Sound gutters and a dry upper floor rule out penetrating damp from above. Condensation does not leave a tide mark, and subsidence is ground movement rather than a moisture route.

  3. Question 3 · Main property defects

    Rachel Iqbal’s survey records cuboidal cracking of cellar joists and grey strands crossing the brickwork towards the next room. The cellar is damp and poorly ventilated. Which defect is most likely?

    1. A.Common furniture beetle, which leaves small round exit holes and fine dust beneath infested timber
    2. B.Surface mould caused by condensation, which affects decoration but does not attack structural timber
    3. C.Dry rot, a fungus that can spread through masonry to other timber if the moisture source is left untreated
    4. D.Wet rot, which stays within the damp timber itself and cannot spread across masonry to other areas

    Answer: C. Dry rot, a fungus that can spread through masonry to other timber if the moisture source is left untreated

    Dry rot is a fungal decay that thrives in damp, unventilated spaces. It can send strands across masonry to reach other timber, so it can weaken structural members well beyond the original damp area. The moisture source must be removed and affected timber treated or replaced. Beetle damage shows exit holes, condensation mould is surface growth, and wet rot is confined to the damp wood.

Keep going

Other MRT1 papers

Independent practice written by Archway Learn. Not an LIBF exam paper, and not affiliated with or endorsed by LIBF.